TN500

Meter Turbidity White Light TN500

Stock:
1 - 9

Add To Quote

Downloads

Description

The TN500 uses a tungsten filament lamp as the light source and 90° scattering method, which is compliant with the U.S EPA 180.1 method for the determination of turbidity in drinking, ground, surface, and saline waters, domestic and industrial wastes. The instrument is designed for water quality professionals, offering long-term reliability in high-accuracy turbidity measurement with an intuitive operation system, simple calibration, and GLP data management.

Technical Data:

Measurement Method90 Degree Measurement, US EPA180.1 Compliant
Light SourceTungsten Filament Lamp
Measuring Range

0 to 1,000 NTU (automatic range switch)

0.01 to 19.99 NTU

20 to 99.9 NTU

100 to 1,000 NTU

Accuracy≤ ±2% of reading+ stray light
Repeatability≤ ± 1% of reading or 0.02 NTU(FNU) (the greater of the two)
Resolution0.01/0.1/1 NTU
Stray Light≤0.02 NTU
Calibration StandardAMCO Polymer or Formazin Solution:0, 20, 100, 400 and 800NTU 
DetectorSilicon photovoltaic
Measuring ModeNormal measurement and TruRead measurement
Data Storage200 groups
Data OutputUSB to PC
Calibration RecordCalibration date and time
DisplayTFT color screen
Sample VialΦ25×60 mm,high borosilicate glass with lid
Sample Vial Volume18 ml
Power Supply3.7V Rechargeable lithium battery
Working Condition

Temperature: 0 to 50°c

Relative humidity:0 to 90% at 30c, 80% at 40c, 0 to 70% at 50c

Instrument Sealing GradeIP67
Dimensions and Weight

Unit: 90 x 203 x 80mm | 385g

With Case: 310 x 295 x 110mm | 1.5kg

AMCO Polymer Standard Calibration Solutions:

Approved by US EPA and ASTM, AMCO high molecular polymer turbidity standard solutions are the best alternatives to Formazin standards in terms of shelf life, ease of use and safety concerns.



Formazin SolutionAMCO Polymer Solutions
ToxicityHighly toxic, PPE is necessary when handlingNon-toxic
OperationRequires diluting, complicated operation.No diluting needed, use directly
Shelf Life

<2 NTU: 1 hour;

2 – 20 NTU: 12 – 24 hours;

20 - 400NTU: 1 month

1 year
Storage ConditionAvoid sunlight at low temperatureAvoid sunlight at room temp.
ConvenienceEasy to settle, requires flipping and mixingVery stable, can be used directly
TraceabilityNon-traceableNIST traceable

Supplied With:

  • TN500 Meter
  • Calibration Standards
  • Sample Cuvettes x 6
  • Microfibre Cloth
  • Silicone Oil
  • Software Flash Drive
  • USB Cable
  • Power adapter
  • Manual
  • Carry Case